石鑫华视觉 手机微信QQ:13450001061

下载中心

宝视纳Basler-Basler blaze固件5.0.0~blaze-firmware-5.0.0.zip

文章来源:石鑫华视觉网时间:2024-11-30 16:19:29 点击:27

宝视纳Basler-Basler blaze固件5.0.0~blaze-firmware-5.0.0.zip

Basler blaze Firmware 5.0.0
2023年9月
5.0.0
Basler blaze ToF相机的固件版本中包括blaze固件更新包、固件更新工具指南以及安装说明。 
此固件版本支持HDR功能。 
在更新固件时,Basler建议也同时更新主机软件。如需详细了解固件和主机软件之间的依赖性关系,请参阅固件版本说明。


Basler blaze固件5.0.0
文件名: blaze-firmware-5.0.0.zip
文件大小: 130590098 字节 (124.54 MB)
修改日期: 2024-03-12 23:25
MD5: bb345c0528a664637d59c818be0080f2
SHA1: 392946e7ba73fe502bf9a53897079a4af9676520
SHA256: 913397ec1bfb06bc8f11ecf789bef59d090418156921df4bcea086a2a9470360
CRC32: 1e39f7fc

Basler官方下载和百度网盘下载:

宝视纳Basler-Basler blaze固件5.0.0~blaze-firmware-5.0.0.zip

http://visionbbs.com/thread-32777-1-1.html

(出处: 石鑫华视觉论坛)


RELEASE NOTES
==============

Basler blaze Firmware

Note: Firmware versions not listed in this document are not released publicly.
      They are created for internal purposes only and don’t contain any changes
      that would affect the behavior of the camera. On occasion, cameras with 
      such a firmware version may be shipped to customers. Updating cameras to a
      higher version than the latest publicly available firmware is not required
      since such an update would not change camera functionality or add new
      features.

Version:           5.0.0
Release date:      2023-09-30
Preceding release: 4.6.2
Products affected: blaze-101 (order number 107796), hardware revisions 09 to 17 
                   blaze-102 (order number 108711), hardware revisions 01 to 04

NEW FEATURES
-------------

*Note:* To use new features introduced by this firmware version, 
you have to update to pylon Supplementary Package for blaze 1.5.0
or above or to Basler blaze SDK 4.5 or above.

* Added the region of interest (ROI) feature. This allows you to specify the
  Width, Height, OffsetX, and OffsetY parameters as required.
* Added the Binning feature. The following parameters allow you to enable and
  control the binning of pixels:
    - BinningHorizontalMode
    - BinningHorizontal
    - BinningVerticalMode
    - BinningVertical
* Added the BslCenterX and BslCenterY parameters to automatically center the ROI
  horizontally and vertically.
* Added the DeviceLinkHeartbeatTimeout parameter allowing you to control the
  length of the timeout used by the camera and the host application to detect a
  network connection loss.
* Added the MinimumWorkingRange parameter, which allows you to shift the 
  camera's working range. The working range can only be shifted when the Fast Mode
  feature is enabled and the Operating Mode is set to 'ShortRange'.
* Added the Image Inpainting filter that fills in gaps by using the depth data
  calculated from neighboring pixels. Image Inpainting is enabled by default.
  If you want the Image Inpainting feature to be disabled by default, set the
  LegacyImagePainting parameter to 'true'. You only have to enable the legacy
  behavior once since the setting is stored permanently in the camera's flash
  memory.
* Added the Illumination Position Correction feature that allows you to correct
  measurement errors caused by the offset between illumination and sensor. The
  feature is enabled by default. If you want the Illumination Position
  Correction feature to be disabled by default, set the
  LegacyIlluminationPositionCorrection parameter to 'true'. You only have to 
  enable the legacy behavior once since the setting is stored permanently in the
  camera's flash memory.
* Added the Multi-Part Streaming Mode feature. If the MultiPartStreaming
  parameter is set to 'On', the camera uses the GigE Vision multi-part
  format for streaming data. Multi-Part Streaming Mode is disabled by
  default.
  Note: This feature is only available when using 3rd-party software that
  accesses the camera directly as a GigE Vision device. When using the pylon
  Supplementary package for blaze or the blaze SDK, the feature is not
  available.
* Added the Trigger Activation feature allowing you to control on which edges
  of an input signal a frame trigger is issued.
* Added the Acquisition Status feature allowing you to check whether the camera
  is currently capturing a frame and whether it is currently waiting for the
  next frame trigger.
* Added 'FrameTriggerWait' as additional source for the digital output.
* Improved IoT security. Numerous measures have been taken for protection
  against attacks via the network and against firmware manipulation.
* Added the WebServerEnable parameter, which can be used to disable the web
  server on the camera that is required for firmware updates and accessing
  diagnostic information.
* Added the Legacy Behavior Control feature. The following parameters allow you
  to change the default behavior of the camera with respect to firmware versions
  below 5.0. Adjustments to these parameters are permanently stored in the
  camera's flash memory.
    - LegacyIntensityScaling
    - LegacyImageInpainting
    - LegacyIlluminationPositionCorrection
* Added the 'IlluminationCalibration' error code to the list of error codes the
  Last Error feature can report.
* Added the PtpClockID, PtpParentClockID, and PtpGrandmasterClockID parameters.
* Added the StartupTime2 parameter allowing you to read out the length of the
  time gap inserted after every 4th image sub-frame.

CHANGES
--------

* Reduced the execution time of the AcquistionStart command.
* Reduced the delay between receiving a software or hardware trigger and
  starting exposure.
* Further optimizations of depth calculation lead to reduced latency (timespan
  from trigger to data received by host).
* Improved compatibility with the Aravis open source software. Aravis failed to
  open a stream when Aravis' access check policy was enabled.
* The time needed for establishing a connection to the camera is slightly
  reduced by providing a compressed camera description XML file.
* Fixed an issue causing streaming data throughput to be limited in case the 
  link speed temporarily dropped from 1 GBit/s to 100 MBit/s.
* Improved conformity with the GenICam Standard Feature Naming Convention (SFNC).
  The camera's feature set now complies with SFNC 2.7.
* Reduced execution time of the PtpDataSetLatch command.
* Improved management of bandwidth consumption in case of a high rate of network
  package drops.
* Fixed an issue causing bright areas to be saturated too early by applying 
  a reduced scaling factor to the intensity data. This change makes 
  intensity images appear slightly darker compared to images taken with 
  firmware versions below 5.0. If your software depends on the brighter images,
  you can set the LegacyIntensityScaling parameter to 'true' to apply the same
  intensity scaling value as in firmware versions below 5.0. You only have to
  enable the legacy behavior once since the setting is stored permanently in
  the camera's flash memory.
* Fixed an issue causing the frame rate to drop when issuing PtpDataSetLatch
  commands while the camera is streaming.
* Fixed occasional camera crashes when accessing digital I/O-related parameters.
* Fixed an issue causing some digital I/O-related parameters not being updated
  properly.
* Fixed an issue caused by over-triggering the camera which prevented streaming
  from being restarted until a ClearLastError command was issued.
* Fixed a rare issue causing the streaming to be stopped unexpectedly.

COMPATIBILITY INFORMATION
--------------------------

*WARNING:* Because of bugs in pylon 7.1 and pylon 7.2, avoid using the blaze
camera with pylon 7.1. or pylon 7.2. Using the latest pylon version or using
pylon 7.0 or below is recommended.
When using pylon 7.1, image acquisition may stop unexpectedly. When using
pylon 7.2, image acquisition may be unstable.

*WARNING:* Once updated, the firmware can't be downgraded to a firmware 
version below 4.2.

*WARNING:* To update the camera's firmware to firmware version 4.0 or above,
the camera's current firmware version has to be at least 2.3.0.
If the current firmware version is below 2.3.0, you first have to update 
the camera to firmware version 3.0.1. Afterwards, you can perform an update 
with the latest camera firmware version. Contact Basler support to get an 
update package for firmware version 3.0.1.

The latest Basler software for blaze cameras can be downloaded here:
http://www.baslerweb.com/blaze-software

*Note:* Applications built using the Basler blaze SDK 3.0.0 or above or the 
pylon Supplementary Package for blaze 1.0.0 or above can't access cameras with
firmware versions below 3.0.0. These cameras have to be updated to firmware 
3.0.0 or above when you migrate to the pylon Supplementary Package for blaze 
1.0.0 or above or to Basler blaze SDK 3.0.0 or above. 
Mixing 2.x cameras with 3.x cameras in the same application is not possible.
Firmware update packages and update instructions can be downloaded here: 
http://www.baslerweb.com/blaze-software