宝视纳Basler-Basler blaze固件5.0.0~blaze-firmware-5.0.0.zip
Basler blaze Firmware 5.0.0
2023年9月
5.0.0
Basler blaze ToF相机的固件版本中包括blaze固件更新包、固件更新工具指南以及安装说明。
此固件版本支持HDR功能。
在更新固件时,Basler建议也同时更新主机软件。如需详细了解固件和主机软件之间的依赖性关系,请参阅固件版本说明。
Basler blaze固件5.0.0
文件名: blaze-firmware-5.0.0.zip
文件大小: 130590098 字节 (124.54 MB)
修改日期: 2024-03-12 23:25
MD5: bb345c0528a664637d59c818be0080f2
SHA1: 392946e7ba73fe502bf9a53897079a4af9676520
SHA256: 913397ec1bfb06bc8f11ecf789bef59d090418156921df4bcea086a2a9470360
CRC32: 1e39f7fc
Basler官方下载和百度网盘下载:
宝视纳Basler-Basler blaze固件5.0.0~blaze-firmware-5.0.0.zip
http://visionbbs.com/thread-32777-1-1.html
(出处: 石鑫华视觉论坛)
RELEASE NOTES
==============
Basler blaze Firmware
Note: Firmware versions not listed in this document are not released publicly.
They are created for internal purposes only and don’t contain any changes
that would affect the behavior of the camera. On occasion, cameras with
such a firmware version may be shipped to customers. Updating cameras to a
higher version than the latest publicly available firmware is not required
since such an update would not change camera functionality or add new
features.
Version: 5.0.0
Release date: 2023-09-30
Preceding release: 4.6.2
Products affected: blaze-101 (order number 107796), hardware revisions 09 to 17
blaze-102 (order number 108711), hardware revisions 01 to 04
NEW FEATURES
-------------
*Note:* To use new features introduced by this firmware version,
you have to update to pylon Supplementary Package for blaze 1.5.0
or above or to Basler blaze SDK 4.5 or above.
* Added the region of interest (ROI) feature. This allows you to specify the
Width, Height, OffsetX, and OffsetY parameters as required.
* Added the Binning feature. The following parameters allow you to enable and
control the binning of pixels:
- BinningHorizontalMode
- BinningHorizontal
- BinningVerticalMode
- BinningVertical
* Added the BslCenterX and BslCenterY parameters to automatically center the ROI
horizontally and vertically.
* Added the DeviceLinkHeartbeatTimeout parameter allowing you to control the
length of the timeout used by the camera and the host application to detect a
network connection loss.
* Added the MinimumWorkingRange parameter, which allows you to shift the
camera's working range. The working range can only be shifted when the Fast Mode
feature is enabled and the Operating Mode is set to 'ShortRange'.
* Added the Image Inpainting filter that fills in gaps by using the depth data
calculated from neighboring pixels. Image Inpainting is enabled by default.
If you want the Image Inpainting feature to be disabled by default, set the
LegacyImagePainting parameter to 'true'. You only have to enable the legacy
behavior once since the setting is stored permanently in the camera's flash
memory.
* Added the Illumination Position Correction feature that allows you to correct
measurement errors caused by the offset between illumination and sensor. The
feature is enabled by default. If you want the Illumination Position
Correction feature to be disabled by default, set the
LegacyIlluminationPositionCorrection parameter to 'true'. You only have to
enable the legacy behavior once since the setting is stored permanently in the
camera's flash memory.
* Added the Multi-Part Streaming Mode feature. If the MultiPartStreaming
parameter is set to 'On', the camera uses the GigE Vision multi-part
format for streaming data. Multi-Part Streaming Mode is disabled by
default.
Note: This feature is only available when using 3rd-party software that
accesses the camera directly as a GigE Vision device. When using the pylon
Supplementary package for blaze or the blaze SDK, the feature is not
available.
* Added the Trigger Activation feature allowing you to control on which edges
of an input signal a frame trigger is issued.
* Added the Acquisition Status feature allowing you to check whether the camera
is currently capturing a frame and whether it is currently waiting for the
next frame trigger.
* Added 'FrameTriggerWait' as additional source for the digital output.
* Improved IoT security. Numerous measures have been taken for protection
against attacks via the network and against firmware manipulation.
* Added the WebServerEnable parameter, which can be used to disable the web
server on the camera that is required for firmware updates and accessing
diagnostic information.
* Added the Legacy Behavior Control feature. The following parameters allow you
to change the default behavior of the camera with respect to firmware versions
below 5.0. Adjustments to these parameters are permanently stored in the
camera's flash memory.
- LegacyIntensityScaling
- LegacyImageInpainting
- LegacyIlluminationPositionCorrection
* Added the 'IlluminationCalibration' error code to the list of error codes the
Last Error feature can report.
* Added the PtpClockID, PtpParentClockID, and PtpGrandmasterClockID parameters.
* Added the StartupTime2 parameter allowing you to read out the length of the
time gap inserted after every 4th image sub-frame.
CHANGES
--------
* Reduced the execution time of the AcquistionStart command.
* Reduced the delay between receiving a software or hardware trigger and
starting exposure.
* Further optimizations of depth calculation lead to reduced latency (timespan
from trigger to data received by host).
* Improved compatibility with the Aravis open source software. Aravis failed to
open a stream when Aravis' access check policy was enabled.
* The time needed for establishing a connection to the camera is slightly
reduced by providing a compressed camera description XML file.
* Fixed an issue causing streaming data throughput to be limited in case the
link speed temporarily dropped from 1 GBit/s to 100 MBit/s.
* Improved conformity with the GenICam Standard Feature Naming Convention (SFNC).
The camera's feature set now complies with SFNC 2.7.
* Reduced execution time of the PtpDataSetLatch command.
* Improved management of bandwidth consumption in case of a high rate of network
package drops.
* Fixed an issue causing bright areas to be saturated too early by applying
a reduced scaling factor to the intensity data. This change makes
intensity images appear slightly darker compared to images taken with
firmware versions below 5.0. If your software depends on the brighter images,
you can set the LegacyIntensityScaling parameter to 'true' to apply the same
intensity scaling value as in firmware versions below 5.0. You only have to
enable the legacy behavior once since the setting is stored permanently in
the camera's flash memory.
* Fixed an issue causing the frame rate to drop when issuing PtpDataSetLatch
commands while the camera is streaming.
* Fixed occasional camera crashes when accessing digital I/O-related parameters.
* Fixed an issue causing some digital I/O-related parameters not being updated
properly.
* Fixed an issue caused by over-triggering the camera which prevented streaming
from being restarted until a ClearLastError command was issued.
* Fixed a rare issue causing the streaming to be stopped unexpectedly.
COMPATIBILITY INFORMATION
--------------------------
*WARNING:* Because of bugs in pylon 7.1 and pylon 7.2, avoid using the blaze
camera with pylon 7.1. or pylon 7.2. Using the latest pylon version or using
pylon 7.0 or below is recommended.
When using pylon 7.1, image acquisition may stop unexpectedly. When using
pylon 7.2, image acquisition may be unstable.
*WARNING:* Once updated, the firmware can't be downgraded to a firmware
version below 4.2.
*WARNING:* To update the camera's firmware to firmware version 4.0 or above,
the camera's current firmware version has to be at least 2.3.0.
If the current firmware version is below 2.3.0, you first have to update
the camera to firmware version 3.0.1. Afterwards, you can perform an update
with the latest camera firmware version. Contact Basler support to get an
update package for firmware version 3.0.1.
The latest Basler software for blaze cameras can be downloaded here:
http://www.baslerweb.com/blaze-software
*Note:* Applications built using the Basler blaze SDK 3.0.0 or above or the
pylon Supplementary Package for blaze 1.0.0 or above can't access cameras with
firmware versions below 3.0.0. These cameras have to be updated to firmware
3.0.0 or above when you migrate to the pylon Supplementary Package for blaze
1.0.0 or above or to Basler blaze SDK 3.0.0 or above.
Mixing 2.x cameras with 3.x cameras in the same application is not possible.
Firmware update packages and update instructions can be downloaded here:
http://www.baslerweb.com/blaze-software